ENET / MAC Fuses brennen ======================== Umgebung: U-Boot (Test mit U-Boot aus BSP Rev.0100) ACHTUNG: Beide MAC-Adressen müssen fortlaufend sein! MAC1 aa:bb:cc:dd:ee:ff MAC2 AA:BB:CC:DD:EE:FF # fuse bank 4 word 2: MAC1 lo # fuse bank 4 word 3: MAC1 hi / MAC2 lo # fuse bank 4 word 4: MAC2 hi # fuse bank 0 word 0: MAC_LOCK 01 (write protect) - read Reference manual for overrride protect fuse prog -y 4 2 ccddeeff fuse prog -y 4 3 EEFFaabb fuse prog -y 4 4 AABBCCDD fuse prog -y 0 0 00000100 Beispiel: --------- MAC0 = 00:d0:93:2c:ba:d2 MAC1 = 00:d0:93:2c:ba:d3 fuse prog -y 4 2 932cbad2 fuse prog -y 4 3 bad300d0 fuse prog -y 4 4 00d0932c fuse prog -y 0 0 00000100