To select the desired boot order set the DIP switch S2 accordingly.
The following boot sequences of the AM335x can be selected by the DIP switch S2 on the MBa335x. Each boot device in a sequence will be searched until a valid boot image is found.
S2 | |||||||||
---|---|---|---|---|---|---|---|---|---|
![]() |
|||||||||
DIP | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | |
ON | • | ||||||||
OFF | • | • | • | • | • | • | • |
S2 | |||||||||
---|---|---|---|---|---|---|---|---|---|
![]() |
|||||||||
DIP | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | |
ON | • | • | |||||||
OFF | • | • | • | • | • | • |
S2 | |||||||||
---|---|---|---|---|---|---|---|---|---|
![]() |
|||||||||
DIP | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | |
ON | • | • | • | ||||||
OFF | • | • | • | • | • |
DIP switch S3 is used to configure the CAN interfaces CAN1 and CAN2.
DIP | OFF (default) | ON |
---|---|---|
S3-1 | CAN1 not terminated | CAN1 terminated (120Ω) |
S3-2 | CAN2 not terminated | CAN2 terminated (120Ω) |
DIP switch S1 is used to configure the CAN frequency.
![]() |
|||||||||
---|---|---|---|---|---|---|---|---|---|
DIP | S1-1 | S1-2 | S1-3 | S1-4 | S1-5 | S1-6 | S1-7 | S1-8 | |
ON | • | • | • | • | • | • | • | • | |
OFF |
![]() |
|||||||||
---|---|---|---|---|---|---|---|---|---|
DIP | S1-1 | S1-2 | S1-3 | S1-4 | S1-5 | S1-6 | S1-7 | S1-8 | |
ON | • | • | • | • | • | • | • | ||
OFF | • |
![]() |
|||||||||
---|---|---|---|---|---|---|---|---|---|
DIP | S1-1 | S1-2 | S1-3 | S1-4 | S1-5 | S1-6 | S1-7 | S1-8 | |
ON | • | • | • | • | • | • | • | ||
OFF | • |
![]() |
|||||||||
---|---|---|---|---|---|---|---|---|---|
DIP | S1-1 | S1-2 | S1-3 | S1-4 | S1-5 | S1-6 | S1-7 | S1-8 | |
ON | • | • | • | • | • | • | |||
OFF | • | • |
DIP switch S4 is used to configure the RS485 interface.
DIP | OFF (default) | ON |
---|---|---|
S4-1 | RS485 RxD not terminated | RS485 RxD terminated (120Ω) |
S4-2 | RS485 TxD not terminated | RS485 TxD terminated (120Ω) |