This is an old revision of the document!
MBa335x DIP switch settings
Boot Device Selection (S2)
To select the desired boot order set the DIP switch S2 accordingly.
The following boot sequences of the AM335x can be selected by the DIP switch S2 on the MBa335x. Each boot device in a sequence will be searched until a valid boot image is found.
MMC0 / SD > SPI0 / NOR > UART0 / n.a. > USB0 / n.a.
DIP | S2-1 | S2-2 | S2-3 | S2-4 | S2-5 | S2-6 | S2-7 | S2-8 | |
---|---|---|---|---|---|---|---|---|---|
ON | • | ||||||||
OFF | • | • | • | • | • | • | • |
MMC1 / eMMC > MMC0 / SD > UART0 / n.a. > USB0 / n.a.
DIP | S2-1 | S2-2 | S2-3 | S2-4 | S2-5 | S2-6 | S2-7 | S2-8 | |
---|---|---|---|---|---|---|---|---|---|
ON | • | • | |||||||
OFF | • | • | • | • | • | • |
SPI0 / NOR > MMC0 / SD > USB0 / n.a. > UART0 / n.a.
DIP | S2-1 | S2-2 | S2-3 | S2-4 | S2-5 | S2-6 | S2-7 | S2-8 | |
---|---|---|---|---|---|---|---|---|---|
ON | • | • | • | ||||||
OFF | • | • | • | • | • |
CAN configuration (S3)
DIP switch S3 is used to configure the CAN interfaces CAN1 and CAN2.
Termination
DIP | OFF (default) | ON |
---|---|---|
S3-1 | CAN0 not terminated | CAN0 terminated (120Ω) |
S3-2 | CAN1 not terminated | CAN1 terminated (120Ω) |
CAN frequency configuration (S1)
DIP switch S1 is used to configure the CAN frequency.
19,2 Mhz
DIP | S1-1 | S1-2 | S1-3 | S1-4 | S1-5 | S1-6 | S1-7 | S1-8 | |
---|---|---|---|---|---|---|---|---|---|
ON | • | • | • | • | • | • | • | • | |
OFF |
24 Mhz (default)
DIP | S1-1 | S1-2 | S1-3 | S1-4 | S1-5 | S1-6 | S1-7 | S1-8 | |
---|---|---|---|---|---|---|---|---|---|
ON | • | • | • | • | • | • | • | ||
OFF | • |
25 Mhz
DIP | S1-1 | S1-2 | S1-3 | S1-4 | S1-5 | S1-6 | S1-7 | S1-8 | |
---|---|---|---|---|---|---|---|---|---|
ON | • | • | • | • | • | • | • | ||
OFF | • |
26 Mhz
DIP | S1-1 | S1-2 | S1-3 | S1-4 | S1-5 | S1-6 | S1-7 | S1-8 | |
---|---|---|---|---|---|---|---|---|---|
ON | • | • | • | • | • | • | |||
OFF | • | • |
RS485 configuration (S4)
DIP switch S4 is used to configure the RS485 interface.
Termination
DIP | OFF (default) | ON |
---|---|---|
S4-1 | RS485 RxD not terminated | RS485 RxD terminated (120Ω) |