MBLS102xA DIP switch settings

WORK IN PROGRESS

To select the desired boot medium set the DIP switches S3, S9 accordingly

S3 S9
DIP 1 2 3 4 1 2 3 4
ON
OFF


DIP switch S2 is used to configure the CAN interfaces CAN0 and CAN1.

DIP OFF (default) ON
S2-1 CAN0 not terminated CAN0 terminated (120Ω)
S2-2 CAN1 not terminated CAN1 terminated (120Ω)

DIP switch S1 is used to configure the RS485 interface.

DIP OFF (default) ON
S1-1 RS485 RxD not terminated RS485 RxD terminated (120Ω)
S1-2 RS485 TxD not terminated RS485 TxD terminated (120Ω)