To select the desired boot medium set the DIP switches S1 and S2 accordingly.
The following boot modes of the AM57XX can be selected by the DIP switches S1 and S2 on the MBa57xx.

S1
DIP 1 2 3 4 5 6 7 8
ON
OFF
S2
DIP 1 2 3 4 5 6 7 8
ON
OFF

S1
DIP 1 2 3 4 5 6 7 8
ON
OFF
S2
DIP 1 2 3 4 5 6 7 8
ON
OFF

S1
DIP 1 2 3 4 5 6 7 8
ON
OFF
S2
DIP 1 2 3 4 5 6 7 8
ON
OFF


DIP switch S3 and S7 is used to configure the CAN interfaces CAN1 and CAN2.
Both switches must be set to ON or OFF otherwise the CAN Bus has an improper termination.

CAN1 (X5)

DIP S3-1 & S3-2
ON CAN Bus not terminated
OFF (default) CAN Bus terminated (120Ω)

CAN2 (X6)

DIP S7-1 & S7-2
ON CAN Bus not terminated
OFF (default) CAN Bus terminated (120Ω)


DIP switch S5 is used to configure the RS485 interface.

DIP S5-1 S5-2
ON RS485 TxD terminated (120Ω) RS485 RxD terminated (120Ω)
OFF (default) RS485 TxD not terminated RS485 RxD not terminated

DIP switch S13 is used to configure the JTAG interface.

DIP S13
ON JTAG via connector X11
OFF JTAG via Micro-USB (x10)