MBa335x DIP switch settings
Boot Device Selection (S2)
To select the desired boot order set the DIP switch S2 accordingly.
The following boot sequences of the AM335x can be selected by the DIP switch S2 on the MBa335x. Each boot device in a sequence will be searched until a valid boot image is found.
MMC0/SD → SPI0/NOR → UART0/n.a. → USB0/n.a.
S2 | |||||||||
---|---|---|---|---|---|---|---|---|---|
![]() |
|||||||||
DIP | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | |
ON | • | ||||||||
OFF | • | • | • | • | • | • | • |
MMC1/eMMC → MMC0/SD → UART0/n.a. → USB0/n.a.
S2 | |||||||||
---|---|---|---|---|---|---|---|---|---|
![]() |
|||||||||
DIP | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | |
ON | • | • | |||||||
OFF | • | • | • | • | • | • |
SPI0/NOR → MMC0/SD → USB0/n.a. → UART0/n.a.
S2 | |||||||||
---|---|---|---|---|---|---|---|---|---|
![]() |
|||||||||
DIP | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | |
ON | • | • | • | ||||||
OFF | • | • | • | • | • |
CAN configuration (S3)
DIP switch S3 is used to configure the CAN interfaces CAN1 and CAN2.
Termination
DIP | OFF (default) | ON |
---|---|---|
S3-1 | CAN1 not terminated | CAN1 terminated (120Ω) |
S3-2 | CAN2 not terminated | CAN2 terminated (120Ω) |
CAN frequency configuration (S1)
DIP switch S1 is used to configure the CAN frequency.
19,2 Mhz
![]() |
|||||||||
---|---|---|---|---|---|---|---|---|---|
DIP | S1-1 | S1-2 | S1-3 | S1-4 | S1-5 | S1-6 | S1-7 | S1-8 | |
ON | • | • | • | • | • | • | • | • | |
OFF |
24 Mhz (default)
![]() |
|||||||||
---|---|---|---|---|---|---|---|---|---|
DIP | S1-1 | S1-2 | S1-3 | S1-4 | S1-5 | S1-6 | S1-7 | S1-8 | |
ON | • | • | • | • | • | • | • | ||
OFF | • |
25 Mhz
![]() |
|||||||||
---|---|---|---|---|---|---|---|---|---|
DIP | S1-1 | S1-2 | S1-3 | S1-4 | S1-5 | S1-6 | S1-7 | S1-8 | |
ON | • | • | • | • | • | • | • | ||
OFF | • |
26 Mhz
![]() |
|||||||||
---|---|---|---|---|---|---|---|---|---|
DIP | S1-1 | S1-2 | S1-3 | S1-4 | S1-5 | S1-6 | S1-7 | S1-8 | |
ON | • | • | • | • | • | • | |||
OFF | • | • |
RS485 configuration (S4)
DIP switch S4 is used to configure the RS485 interface.
Termination
DIP | OFF (default) | ON |
---|---|---|
S4-1 | RS485 RxD not terminated | RS485 RxD terminated (120Ω) |
S4-2 | RS485 TxD not terminated | RS485 TxD terminated (120Ω) |
Disclaimer
TQ-Systems GmbH provides the Board Support Packages (BSP) free of charge. The software included in the shipment has been configured individually for the starter kits. The software is only intended to evaluate the module. The use of the Board Support Packages (BSP) is only allowed within the scope of functionality described by TQ-Systems GmbH. TQ-Systems GmbH does not accept any liability for all further changes of the Board Support Package and for any damage resulting from its use.
TQ-Systems GmbH provides the Board Support Packages (BSP) free of charge. The software included in the shipment has been configured individually for the starter kits. The software is only intended to evaluate the module. The use of the Board Support Packages (BSP) is only allowed within the scope of functionality described by TQ-Systems GmbH. TQ-Systems GmbH does not accept any liability for all further changes of the Board Support Package and for any damage resulting from its use.